product info |
 NAME CJX2 AC Contactors  DOWNLOAD PDF  PRODUCT TYPE Contactor  AC Contactor  MODEL CJX2-D09 CJX2-D12 CJX2-D18 CJX2-D25 CJX2-D32 CJX2-D40 CJX2-D50 CJX2-D65 CJX2-D80 CJX2-D95 CJX2-D115 CJX2-D150 CJX2-D170 CJX2-D205 CJX2-D245 CJX2-D300 CJX2-D410 CJX2-D475 CJX2-D620
|
| |
|
|
1.Application
CJX2 series AC Contactor is suitable for using in the circuits up to the rated voltage 660V AC50Hz or 60Hz, rated current up to 620A, for making, breaking, frequently starting & controllingthe AC motor. Combined with the auxiliary contact block, timer delay & machine-interlockingdevice etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter.With the thermal relay, it is combined into the electromagnetic starter. The product conforms toIEC60947-4-1 stardand.
2. Specification
| Type |
CJX2-D09 |
CJX2-D12 |
CJX2-D18 |
CJX2-D25 |
CJX2-D32 |
CJX2-D40 |
CJX2-D50 |
CJX2-D65 |
CJX2-D80 |
CJX2-D95 |
| Rated workingcurrent (A) |
AC3 |
9 |
12 |
18 |
25 |
32 |
40 |
50 |
65 |
80 |
95 |
| AC4 |
3.5 |
5 |
7.7 |
8.5 |
12 |
18.5 |
24 |
28 |
37 |
44 |
| Standardpower ratingsof 3-phasemotors50/60Hz incategory AC-3 |
220/230V |
2.2 |
3 |
4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
25 |
| 380/400V |
4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
| 415V |
4 |
5.5 |
9 |
11 |
15 |
22 |
25 |
37 |
45 |
45 |
| 500V |
5.5 |
7.5 |
10 |
15 |
18.5 |
22 |
30 |
37 |
55 |
55 |
| 660/690V |
5.5 |
7.5 |
10 |
15 |
18.5 |
30 |
33 |
37 |
45 |
55 |
| Rated heat current (A) |
20 |
20 |
32 |
40 |
50 |
60 |
80 |
80 |
125 |
125 |
| Electrical life |
AC3 (x104) |
100 |
100 |
100 |
100 |
80 |
80 |
60 |
60 |
60 |
60 |
| AC4 (x104) |
20 |
20 |
20 |
20 |
20 |
15 |
15 |
15 |
10 |
10 |
| Mechanical life (x104) |
1000 |
1000 |
1000 |
1000 |
800 |
800 |
800 |
800 |
600 |
600 |
| Number of the contacts |
3P+NO |
3P+NC+NO |
| 3P+NC |
| Type |
CJX2-D115 |
CJX2-D150 |
CJX2-D170 |
CJX2-D205 |
CJX2-D245 |
CJX2-D300 |
CJX2-D410 |
CJX2-D475 |
CJX2-D620 |
| Rated workingcurrent (A) |
AC3 |
115 |
150 |
170 |
205 |
245 |
300 |
410 |
475 |
620 |
|
AC4 |
52 |
60 |
75 |
85 |
105 |
117 |
138 |
147 |
180 |
| Standard powerratings of 3-phase motors50/60Hz incategory AC-3 |
220/230V |
30 |
40 |
55 |
63 |
75 |
100 |
110 |
147 |
200 |
| 380/400V |
55 |
75 |
90 |
110 |
132 |
160 |
220 |
265 |
335 |
| 415V |
59 |
80 |
100 |
110 |
132 |
180 |
220 |
280 |
375 |
| 500V |
75 |
90 |
110 |
129 |
160 |
200 |
250 |
355 |
400 |
| 660/690V |
80 |
100 |
110 |
129 |
160 |
220 |
280 |
355 |
450 |
| Rated heat current (A) |
200 |
250 |
250 |
275 |
315 |
400 |
500 |
700 |
1000 |
| Electrical life |
AC3 (x104) |
200 |
60 |
60 |
50 |
50 |
50 |
30 |
30 |
20 |
| AC4 (x104) |
15 |
15 |
15 |
15 |
15 |
15 |
8 |
8 |
5 |
| Mechanical life (x104) |
300 |
300 |
300 |
300 |
300 |
300 |
300 |
100 |
100 |
100 |
3. Standard Control Circuit Voltage
| Volts |
24 |
42 |
48 |
110 |
220 |
230 |
240 |
380 |
400 |
415 |
440 |
500 |
600 |
| 50Hz |
B5 |
D5 |
E5 |
F5 |
M5 |
P5 |
U5 |
Q5 |
V5 |
N5 |
R5 |
S5 |
Y5 |
| 60Hz |
B6 |
D6 |
E6 |
F6 |
M6 |
- |
U6 |
Q6 |
- |
- |
R6 |
- |
- |
| 50/60Hz |
B7 |
D7 |
E7 |
F7 |
M7 |
P7 |
U7 |
Q7 |
V7 |
N7 |
R7 |
- |
- |
4. Outline and Mounting Dimension
| Type |
A |
B |
C |
D |
E |
a |
b |
Φ |
| CJX2-D09~12 |
47 |
76 |
82 |
113 |
133 |
34/35 |
50/60 |
4.5 |
| CJX2-D18 |
47 |
76 |
87 |
118 |
138 |
34/35 |
50/60 |
4.5 |
| CJX2-D25 |
57 |
86 |
95 |
126 |
146 |
40 |
48 |
4.5 |
| CJX2-D32 |
57 |
86 |
100 |
131 |
151 |
40 |
48 |
4.5 |
| CJX2-D40~65 |
77 |
129 |
116 |
145 |
165 |
40 |
100/110 |
6.5 |
| CJX2-D80~95 |
87 |
129 |
127 |
175 |
195 |
40 |
100/110 |
6.5 |
| Type |
A |
B |
C |
b1 |
P |
Q |
S |
Q1 |
M |
N |
L |
Φ |
Ga |
Ha |
| CJX2-D115 |
158 |
120 |
132 |
158 |
35 |
60 |
17 |
25 |
134 |
96.2 |
75 |
M6 |
- |
- |
| CJX2-D150 |
158 |
120 |
132 |
158 |
35 |
60 |
17 |
25 |
134 |
96.2 |
75 |
M6 |
- |
- |
| CJX2-D170 |
158 |
120 |
132 |
158 |
35 |
60 |
17 |
25 |
134 |
96.2 |
75 |
M6 |
- |
- |
| CJX2-D205 |
168.5 |
174 |
181 |
137 |
40 |
69 |
20 |
59.4 |
154 |
127 |
113.5 |
M8 |
80 |
120-106 |
| CJX2-D245 |
168.5 |
197 |
181 |
137 |
48 |
69 |
25 |
51.5 |
172 |
127 |
113.5 |
M10 |
80 |
120-106 |
| CJX2-D300 |
213 |
206 |
219 |
145 |
48 |
91 |
25 |
74 |
181 |
158 |
145 |
M10 |
80 |
120-106 |
| CJX2-D410 |
213 |
206 |
219 |
209 |
48 |
91 |
25 |
74 |
181 |
158 |
145 |
M10 |
80 |
120-106 |
| CJX2-D475 |
233 |
238 |
232 |
209 |
55 |
108 |
30 |
77 |
208 |
172 |
146 |
M10 |
80 |
180 |
| CJX2-D620 |
309 |
304 |
255 |
280 |
80 |
140 |
40 |
89 |
264 |
202 |
155 |
M12 |
80 |
180 |
5. Auxiliary contact block
| Appellation |
Type |
|
Auxiliary instantaneous
contactor block,contactor I |
LA1-DN10C |
 |
| LA1-DN01C |
| Appellation |
Type |
|
Auxiliary instantaneous
contactor block,contactor II |
LA1-DN11C |
 |
| LA1-DN20C |
| LA1-DN02C |
| Appellation |
Type |
|
Auxiliary instantaneous
contactor block,contactor IV |
LA1-DN40C |
 |
| LA1-DN31C |
| LA1-DN22C |
| LA1-DN13C |
| LA1-DN04C |
| Appellation |
Type |
|
Auxiliary instantaneous
contactor block,contactor IV |
LA1-DN40C |
 |
| LA1-DN31C |
| LA1-DN22C |
| LA1-DN13C |
| LA1-DN04C |
| Appellation |
Type |
|
| Side-mounted auxiliary module |
LA8-DN11C |
 |
| LA8-DN20C |
6. LA2 time delay auxiliary contact block
| Appellation |
Type |
|
| Auxiliary instantaneouscontactor block,contactor IV |
0.1...3S LA2-DT0 |
 |
| 0.1...30S LA2-DT2 |
| 10...180S LA2-DT4 |
| 1...30S LA2-DS2 |
| Appellation |
Type |
|
| Time delay auxiliary contactorblock releasing and delay |
0.1...3S LA2-DT0 |
 |
| 0.1...30S LA3-DT2 |
| 10...180S LA3-DT4 |
| Contactor |
|
Auxiliary Blocks |
|
Relative products |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
|
|
|