product info
  NAME
HGL Series Solid State Relay
  DOWNLOAD PDF
  PRODUCT TYPE
Relay
    Solid State Relay
  MODEL
HGL
description
FEATURES :
  • TRIAC output(AC), zero voltage turn-on, zero current turn-off(minimizes EMI/RFI)
  • Bipolar transistor output(DC),on-state voltage drop low, switching speedily
  • Internal RC snubber
  • High dv/dt and high blocking voltage .
  • Low Input power Consumption, TTL and CMOS Compatibl.
  • Input and output 4000V optically isolated .
  • High Surge Rating Allows Lamp and Motor Load Switching.
  • 100% tested at rated current , CE compliant .
  • PCB Mount, standard modulus .
  • Application :
      HGL Series Solid State Relays, adapt ignition-proof engineering cover, filled with EPOXY, PCB mounting, standard modulus. This series have the features of noiseless switching, no contact dithering, no electric arc, long life, high reliability comparing with electromagnet relays. Input current small convenient to interface with terminals of computer and various digital telecontrol circuit. This products are widely used in the fields of petrochemical equipment, foodstuff-producing mechanism, packaging machines, textile and plastic mechanisms, tool numerical control, gymnasium e qup. Specialities be the same with canker,aquosity request prevent explode scurvines circum-stance, and often switch of occasione .
     
    SELECTING CODE :
    PRECAUTIONS :
  • When controlling AC inductive load, the SSR may be damaged by the high transient voltage and surge current added on the output, so some special clamping devices to control voltage, such as zener diode, varistor .
  • When controlling DC inductive load, such as solenoid, motor starter, etc, a continuous current circuit should be used to control the reverse electric motor force. Generally speaking, a simple way is to parallel the load with a diode inversely, but thus will affect the release time of inductive load. A better way is to series a diode with a zener diode inversely or to series a diode with a resistance .
  • When controlling a small current(close to Min. load current),a dummy resistance should be paralleled to reduce the rest voltage produced by the surge current on the output.
  • When a jointing type relay is mounted, the temperature should be controlled under 260 centigrade degrees and the time will be limited within 5second.
  • To avoid the temperature exceeding the allowance, heatsink efficiency and the mounting position should be regarded, suitable space will be left when two or more SSR are mounted .
  • Output parameters(T=25℃) :
    Output current type 1 2 3
    Operating voltage range 2:28 280VAC 3:48 480VAC
    Max. Load current 1A 2A 3A
    Max. Surge current-Non repetitive (10ms) 80Apk 120Apk 160Apk
    2Max. I t for fusing(10ms) 2 32A2s 2 72A2s 1282A2s
    Min. Off-state dv/dt 250V/usec 250V/usec 500V/usec
    Max. Over-zero voltage ±35VAC
    Min. Load current 100mA
    Max. On-state voltage drop 1.5VAC@rated current
    Max. Off-state leakage current 5mA,1mA /no RC @rated voltage
    Transient over voltage 2:800Vpk 3:1000Vpk
    Operating frequency range 47- 63Hz
    Dielectric strength 50Hz 1Min( ) 4000VAC input-output 2500VAC input/output-base
    Insulation resistance 1000MQ 500VDC Voltage Test
    Vibration resistance Destructive Functional 117.6mm/s2(12G),10-55 Hz double Amplitude of 2 mm 117.6mm/s2(12G),10-55 Hz double Amplitude of 2 mm
    Destructive FunctionalShock resistance Min.980m/s2(100G)(5 times each for X,Y,Z axis) Min.980m/s2(100G)(4 times each for X,Y,Z axis)
    Max. Capacitance 8pF input-output
    Max. Turn-on time Zero voltage turn-on (1/2 cycle of load power)+1msec(DC input) (3/2 cycle of load power)+1msec(AC input)
    Random turn-on 1msec
    Max. Turn-off time (1/2 cycle of load power)+1msec(DC input) (3/2 cycle of load power)+1msec(AC input)
    Ambient operating temperature -30 ℃to 80℃
    Ambient storage temperature -30℃ to 120 ℃
    Ambient humidity relative 45% to 85%
    Weight typical ≤85g
    Dimensions :